Assessment Year | 2005 |
---|---|
Principal Product | Grilles and registers |
NAICS | 332323: Ornamental and Architectural Metal Work Manufacturing |
SIC | 3446: Architectural and Ornamental Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
140,000
ft2
|
Annual Production | 13,700,000
pieces
|
Production Hrs. Annual | 5,976
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $424,554 | 4,478,442 |
kWh
|
$0.095 |
Natural Gas | $26,987 | 3,228 |
MMBtu
|
$8.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $90,690 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 4.131: Modify process to reduce material use/cost | $60,950 | - | - | - | $60,950 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,578 | $45,427 |
$14,578
133,079
kWh
|
- | - | |
03 | 2.2136: Install / repair insulation on steam lines | $6,521 | $11,360 | - |
$6,521
-
MMBtu
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,338 | $3,000 |
$4,338
45,665
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,106 | $50 |
$4,106
43,225
kWh
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $197 | $97 |
$197
12,430
kWh
|
- | - | |
TOTAL RECOMMENDED | $90,690 | $59,934 |
$23,219
234,399
kWh
|
$6,521
-
MMBtu
|
$60,950 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs