| Assessment Year | 2005 |
|---|---|
| Principal Product | Coin and Currency Handling Equipment |
| NAICS | 333318: Other Commercial and Service Industry Machinery Manufacturing |
| SIC | 3578: Calculating and Accounting Machines, Except Electronic Computers |
| Sales Range | $100 M to 500M |
| # of Employees | 100 |
| Plant Area |
128,000
ft2
|
| Annual Production | 240,000
pieces
|
| Production Hrs. Annual | 2,168
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,534 | 735,300 |
kWh
|
$0.065 |
| Electricity Demand | $2,122 | 2,268 |
kW-mo/yr
|
$0.94 |
| Electricity Fees | $19,779 | - |
|
- |
| Natural Gas | $4,199 | 587 |
MMBtu
|
$7.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $201,869 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.131: Modify process to reduce material use/cost | $200,000 | $19,000 | - | - | $200,000 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $861 | $1,632 |
$797
12,332
kWh
|
$64
-
kW-mo/yr
|
- | |
| 03 | 2.9112: Use solar heat to heat water | $690 | $1,100 |
$690
10,687
kWh
|
- | - | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $318 | $506 |
$294
5,443
kWh
|
$24
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $201,869 | $22,238 |
$1,781
28,462
kWh
|
$88
-
kW-mo/yr
|
$200,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs