| Assessment Year | 2004 |
|---|---|
| Principal Product | Packaged Salad |
| NAICS | 311991: Perishable Prepared Food Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 250 |
| Plant Area |
225,000
ft2
|
| Annual Production | 13,000,000
pieces
|
| Production Hrs. Annual | 6,489
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $646,120 | 11,450,100 |
kWh
|
$0.056 |
| Electricity Demand | $41,538 | 25,550 |
kW-mo/yr
|
$1.63 |
| Electricity Fees | $62,650 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,315,434 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $43,207 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $34,302 | $480 |
$29,114
622,087
kWh
|
$5,188
-
kW-mo/yr
|
- | |
| 02 | 4.441: Install automatic packing equipment | $3,270,456 | $3,624,320 | - | - | $3,270,456 | |
| 03 | 2.6218: Turn off equipment when not in use | $1,133 | $506 |
$1,133
24,204
kWh
|
- | - | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $2,081 | $499 |
$1,766
37,728
kWh
|
$315
-
kW-mo/yr
|
- | |
| 05 | 2.2515: Use optimum thickness insulation | $638 | $360 |
$521
11,137
kWh
|
$117
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,918 | $12,008 |
$2,477
52,931
kWh
|
$441
-
kW-mo/yr
|
- | |
| 07 | 2.4133: Use most efficient type of electric motors | $3,906 | $6,178 |
$3,282
70,136
kWh
|
$624
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $3,315,434 | $3,644,351 |
$38,293
818,223
kWh
|
$6,685
-
kW-mo/yr
|
$3,270,456 | ||
| TOTAL IMPLEMENTED | $43,207 | $19,165 |
$36,639
782,882
kWh
|
$6,568
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs