Assessment Year | 2004 |
---|---|
Principal Product | Raw Milk |
NAICS | 112120: Dairy Cattle and Milk Production |
SIC | 241: Logging |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
1,000,000
ft2
|
Annual Production | 84,862,500
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $176,980 | 4,657,360 |
kWh
|
$0.038 |
Electricity Demand | $125,837 | 14,139 |
kW-mo/yr
|
$8.90 |
Electricity Fees | $3,564 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $209,120 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,874 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $996 | $691 |
$609
15,120
kWh
|
$387
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $198 | $120 |
$144
3,572
kWh
|
$54
-
kW-mo/yr
|
- | |
03 | 2.9112: Use solar heat to heat water | $868 | $1,530 | - | - |
$868
-
MMBtu
|
|
04 | 2.1331: Burn a less expensive grade of fuel | $170,924 | $52,200 |
$128,340
3,184,617
kWh
|
$41,269
-
kW-mo/yr
|
$1,315
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,394 | $17,193 |
$10,135
251,486
kWh
|
$3,259
-
kW-mo/yr
|
- | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $260 | $(-220.0) |
$165
5,124
kWh
|
$95
-
kW-mo/yr
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $22,480 | $10,717 |
$19,552
423,213
kWh
|
$2,928
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $209,120 | $82,231 |
$158,945
3,883,132
kWh
|
$47,992
-
kW-mo/yr
|
$2,183
-
MMBtu
|
||
TOTAL IMPLEMENTED | $35,874 | $27,910 |
$29,687
674,699
kWh
|
$6,187
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs