Assessment Year | 2003 |
---|---|
Principal Product | Citrus Juices |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
40,000
ft2
|
Annual Production | 2,000
Tgal
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $103,629 | 1,790,400 |
kWh
|
$0.058 |
Electricity Demand | $11,142 | 4,385 |
kW-mo/yr
|
$2.54 |
Electricity Fees | $8,314 | - |
|
- |
Natural Gas | $24,396 | 4,214 |
MMBtu
|
$5.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,349 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,811 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2441: Preheat boiler makeup water with waste process heat | $14,811 | $5,240 | - | - |
$14,811
-
MMBtu
|
- | |
02 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $36,297 | $90,000 |
$103,629
1,790,000
kWh
|
$11,142
-
kW-mo/yr
|
$(-78,474.0)
-
MMBtu
|
- | |
03 | 2.1221: Replace obsolete burners with more efficient ones | $3,275 | $4,395 | - | - |
$3,275
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,352 | $9,037 |
$577
14,582
kWh
|
$352
-
kW-mo/yr
|
- | $423 | |
05 | 2.7145: Install skylights | $708 | $3,395 |
$708
17,885
kWh
|
- | - | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $567 | $1,500 |
$299
7,552
kWh
|
$268
-
kW-mo/yr
|
- | - | |
07 | 2.4133: Use most efficient type of electric motors | $339 | $460 |
$279
7,045
kWh
|
$60
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $57,349 | $114,027 |
$105,492
1,837,064
kWh
|
$11,822
-
kW-mo/yr
|
$(-60,388.0)
-
MMBtu
|
$423 | ||
TOTAL IMPLEMENTED | $14,811 | $5,240 | - | - |
$14,811
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs