| Assessment Year | 2003 | 
|---|---|
| Principal Product | Milk | 
| NAICS | 112120: Dairy Cattle and Milk Production | 
| SIC | 241: Logging | 
| Sales Range | $1 M  to 5M  | 
    
| # of Employees | 10 | 
| Plant Area | 
                            1,400,000
                 
ft2
 
                     | 
    
| Annual Production | 19,400,000
             
lb
 
         | 
    
| Production Hrs. Annual | 5,840
             
hrs
 
         | 
    
| Location (State) | Arizona | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $57,413 | 850,781 | 
             
kWh
 
         | 
        $0.067 | 
| Electricity Demand | $14,196 | 1,917 | 
             
kW-mo/yr
 
         | 
        $7.41 | 
| Electricity Fees | $3,065 | - | 
             | 
        - | 
| Natural Gas | $573 | 46 | 
             
MMBtu
 
         | 
        $12.46 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $91,379 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $5,768 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Increase in Production Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.451: Add additional production shift | $66,315 | $18,116 | - | - | - | - | $66,315 | |
| 02 | 4.111: Add equipment/ operators to reduce production bottleneck | $11,700 | $18,000 | - | - | - | - | $11,700 | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,140 | $60 | 
                        $3,837
                                                     7,464
                                 
                                            
kWh
 
                             | 
                                                                                
                        $303
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,660 | $7,180 | 
                        $3,349
                                                     65,159
                                 
                                            
kWh
 
                             | 
                                                                                
                        $3,311
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 05 | 4.631: Install an uninteruptable power supply | $1,275 | $573 | - | - | - | $1,275 | - | |
| 06 | 2.9112: Use solar heat to heat water | $468 | $1,730 | - | - | 
                        $468
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | - | |
| 07 | 2.2222: Convert liquid heaters from underfiring to immersion or submersion heating | $468 | $1,150 | - | - | 
                        $468
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $353 | $1,640 | 
                        $246
                                                     6,482
                                 
                                            
kWh
 
                             | 
                                                                                
                        $107
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| TOTAL RECOMMENDED | $91,379 | $48,449 | 
                        $7,432
                                                     79,105
                                 
                                            
kWh
 
                             | 
                                                                                
                        $3,721
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                
                        $936
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                $1,275 | $78,015 | ||
| TOTAL IMPLEMENTED | $5,768 | $2,273 | 
                        $4,083
                                                     13,946
                                 
                                            
kWh
 
                             | 
                                                                                
                        $410
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | $1,275 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs