| Assessment Year | 2003 |
|---|---|
| Principal Product | Laundry for Uniforms and Work Clothing |
| NAICS | 315210: Cut and Sew Apparel Contractors |
| SIC | 2326: Men's and Boys' Work Clothing |
| Sales Range | $5 M to 10M |
| # of Employees | 85 |
| Plant Area |
30,000
ft2
|
| Annual Production | 7,150,000
lb
|
| Production Hrs. Annual | 3,654
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,967 | 594,120 |
kWh
|
$0.072 |
| Electricity Demand | $1,267 | 2,816 |
kW-mo/yr
|
$0.45 |
| Electricity Fees | $18,242 | - |
|
- |
| Natural Gas | $84,938 | 15,562 |
MMBtu
|
$5.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,533 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,483 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2136: Install / repair insulation on steam lines | $168 | $350 | - | - |
$168
-
MMBtu
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,025 | $30 |
$1,009
13,121
kWh
|
$16
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $1,305 | $1,400 |
$1,287
16,741
kWh
|
$18
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $11,899 | $17,550 |
$11,664
151,699
kWh
|
$235
-
kW-mo/yr
|
- | - | - | |
| 05 | 4.514: Re-arrange equipment layout to reduce handling costs | $2,290 | $482 | - | - | - | $2,290 | - | |
| 06 | 4.111: Add equipment/ operators to reduce production bottleneck | $2,846 | $1,000 | - | - | - | - | $2,846 | |
| TOTAL RECOMMENDED | $19,533 | $20,812 |
$13,960
181,561
kWh
|
$269
-
kW-mo/yr
|
$168
-
MMBtu
|
$2,290 | $2,846 | ||
| TOTAL IMPLEMENTED | $3,483 | $862 |
$1,009
13,121
kWh
|
$16
-
kW-mo/yr
|
$168
-
MMBtu
|
$2,290 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs