Assessment Year | 2003 |
---|---|
Principal Product | Juice bottling |
NAICS | 333993: Packaging Machinery Manufacturing |
SIC | 3565: Packaging Machinery |
Sales Range | $100 M to 500M |
# of Employees | 146 |
Plant Area |
380,000
ft2
|
Annual Production | 17,000,000
units
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $770,293 | 12,002,128 |
kWh
|
$0.064 |
Electricity Demand | $72,456 | 18,829 |
kW-mo/yr
|
$3.85 |
Electricity Fees | $118,764 | - |
|
- |
Natural Gas | $23,786 | 2,325 |
MMBtu
|
$10.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,543,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $38,102 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $758 | $975 |
$758
11,049
kWh
|
- | - | - | - | |
02 | 2.7145: Install skylights | $15,856 | $33,200 | n/a |
$15,856
263,822
kWh
|
- | - | - | - |
03 | 2.2511: Insulate bare equipment | $6,729 | $9,784 | n/a |
$5,648
93,980
kWh
|
$1,081
-
kW-mo/yr
|
- | - | - |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,062 | $56 |
$5,533
92,058
kWh
|
$529
-
kW-mo/yr
|
- | - | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $16,556 | $1,316 |
$15,378
255,878
kWh
|
$1,178
-
kW-mo/yr
|
- | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $6,435 | $5,084 |
$5,758
95,810
kWh
|
$677
-
kW-mo/yr
|
- | - | - | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $4,638 | $7,500 |
$4,157
36,216
kWh
|
$481
-
kW-mo/yr
|
- | - | - | |
08 | 2.3416: Use combined cycle gas turbine generator sets with waste heat boilers connected to turbine exhaust | $878,532 | $1,880,000 | n/a |
$990,000
11,000,000
kWh
|
$72,456
-
kW-mo/yr
|
- | $(-183,924.0) | - |
09 | 3.4151: Minimize water usage | $3,515 | - | - | - |
$3,515
-
Tgal
|
- | - | |
10 | 3.4151: Minimize water usage | $138 | $60 | - | - |
$138
-
Tgal
|
- | - | |
11 | 4.611: Begin a practice of predictive / preventative maintenance | $603,884 | $11,220 | - | - | - | - | $603,884 | |
TOTAL RECOMMENDED | $1,543,103 | $1,949,195 |
$1,043,088
11,848,813
kWh
|
$76,402
-
kW-mo/yr
|
$3,653
-
Tgal
|
$(-183,924.0) | $603,884 | ||
TOTAL IMPLEMENTED | $38,102 | $14,991 |
$31,584
491,011
kWh
|
$2,865
-
kW-mo/yr
|
$3,653
-
Tgal
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs