Assessment Year | 2003 |
---|---|
Principal Product | Deli Sandwiches |
NAICS | 311991: Perishable Prepared Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
55,000
ft2
|
Annual Production | 52,000,000
pieces
|
Production Hrs. Annual | 2,921
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $218,227 | 3,638,600 |
kWh
|
$0.060 |
Electricity Demand | $14,066 | 8,484 |
kW-mo/yr
|
$1.66 |
Electricity Fees | $17,038 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $586,538 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $853 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,753 | $8,149 |
$928
20,129
kWh
|
$739
-
kW-mo/yr
|
- | - | - | $86 | - | |
02 | 2.7135: Install occupancy sensors | $500 | $750 |
$500
10,850
kWh
|
- | - | - | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $813 | $2,376 |
$477
10,338
kWh
|
$336
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $497 | $30 |
$292
6,325
kWh
|
$205
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,918 | $6,084 |
$2,298
49,851
kWh
|
$1,620
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $853 | - |
$853
18,502
kWh
|
- | - | - | - | - | - | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $3,367 | $3,600 |
$2,114
45,860
kWh
|
$1,253
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.7145: Install skylights | $751 | $1,958 |
$751
16,299
kWh
|
- | - | - | - | - | - | |
09 | 2.4314: Use synthetic lubricant | $969 | $3,231 |
$289
4,818
kWh
|
$131
-
kW-mo/yr
|
$549
-
gal
|
- | - | - | - | |
10 | 2.7111: Reduce illumination to minimum necessary levels | $3,251 | $387 |
$1,682
44,505
kWh
|
$1,569
-
kW-mo/yr
|
- | - | - | - | - | |
11 | 4.441: Install automatic packing equipment | $258,120 | $14,080 | n/a | - | - | - | $258,120 | - | - | - |
12 | 4.441: Install automatic packing equipment | $37,933 | $57,000 | n/a | - | - | - | $37,933 | - | - | - |
13 | 4.441: Install automatic packing equipment | $15,933 | $22,000 | n/a | - | - | - | $15,933 | - | - | - |
14 | 4.125: | $88,920 | $1,140 | - | - | - | - | - | - | $88,920 | |
15 | 4.521: Clear and rent existing space | $168,960 | $8,364 | - | - | - | - | $168,960 | - | - | |
TOTAL RECOMMENDED | $586,538 | $129,149 |
$10,184
227,477
kWh
|
$5,853
-
kW-mo/yr
|
$549
-
gal
|
$311,986 | $168,960 | $86 | $88,920 | ||
TOTAL IMPLEMENTED | $853 | - |
$853
18,502
kWh
|
- | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs