ITAC Assessment: AS0337
ITAC logo
ITAC Assessment: AS0337
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Trusses
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 105,720
ft2
Annual Production 20,350
thousand feet
Production Hrs. Annual 6,100
hrs
Location (State) Nevada

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $82,975 1,294,068
kWh
Electricity Demand $5,744 2,834
kW-mo/yr
Electricity Fees $16,078 -
Natural Gas $3,654 391
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $58,829 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $23,605 $180 $19,957
275,720
kWh
$3,648
-
kW-mo/yr
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $1,017 $11 $775
10,715
kWh
$242
-
kW-mo/yr
-
03 2.7135: Install occupancy sensors $543 $1,875 $385
5,318
kWh
$158
-
kW-mo/yr
-
04 2.4133: Use most efficient type of electric motors $209 $164 $177
2,449
kWh
$32
-
kW-mo/yr
-
05 2.7232: Replace existing hvac unit with high efficiency model $3,723 $16,500 $2,841
39,268
kWh
$882
-
kW-mo/yr
-
06 2.6218: Turn off equipment when not in use $3,736 $4,622 $3,736
51,616
kWh
- -
07 2.6218: Turn off equipment when not in use $3,565 $60 $3,565
49,249
kWh
- -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $11,034 $5,800 $9,624
132,973
kWh
$1,410
-
kW-mo/yr
-
09 3.6124: Burn waste oil for heat $5,757 $9,000 $536
7,411
kWh
$497
-
kW-mo/yr
$4,724
10 3.5242: Recover metals from spent solutions and recycle $5,640 $60 - - $5,640
TOTAL RECOMMENDED $58,829 $38,272 $41,596
574,719
kWh
$6,869
-
kW-mo/yr
$10,364
TOTAL IMPLEMENTED $35,855 $21,537 $31,051
429,017
kWh
$4,804
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs