| Assessment Year | 2002 |
|---|---|
| Principal Product | High performance cameras and fingerprint analysis machines |
| NAICS |
n/a
|
| SIC | 3861: Photographic Equipment and Supplies |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
37,346
ft2
|
| Annual Production | 1,500
pieces
|
| Production Hrs. Annual | 2,718
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $67,890 | 1,080,160 |
kWh
|
$0.063 |
| Electricity Demand | $21,460 | 2,430 |
kW-mo/yr
|
$8.83 |
| Electricity Fees | $8,779 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,846 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $400 | $1,425 |
$400
5,887
kWh
|
- | |
| 02 | 2.7212: Install or upgrade insulation on hvac distribution systems | $501 | $200 |
$427
6,269
kWh
|
$74
-
kW-mo/yr
|
|
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $17,394 | $32,550 |
$13,798
202,823
kWh
|
$3,596
-
kW-mo/yr
|
|
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $7,813 | - |
$7,813
114,840
kWh
|
- | |
| 05 | 2.4323: Use optimum size and capacity equipment | $5,738 | $15,320 |
$4,710
69,232
kWh
|
$1,028
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $31,846 | $49,495 |
$27,148
399,051
kWh
|
$4,698
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs