Assessment Year | 2002 |
---|---|
Principal Product | Canvas boat tops and covers |
NAICS |
n/a
|
SIC | 2394: Canvas and Related Products |
Sales Range | $10 M to 50M |
# of Employees | 103 |
Plant Area |
46,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 4,572
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,946 | 407,048 |
kWh
|
$0.064 |
Electricity Demand | $3,800 | 1,544 |
kW-mo/yr
|
$2.46 |
Electricity Fees | $2,805 | - |
|
- |
Natural Gas | $5,366 | 472 |
MMBtu
|
$11.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,179 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $909 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $909 | $4,165 |
$615
10,719
kWh
|
$247
-
kW-mo/yr
|
- | $47 | |
02 | 2.7135: Install occupancy sensors | $373 | $1,050 |
$373
6,175
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,133 | $750 |
$904
14,952
kWh
|
$229
-
kW-mo/yr
|
- | - | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $580 | $1,750 |
$404
7,147
kWh
|
$176
-
kW-mo/yr
|
- | - | |
05 | 4.424: Improve space comfort conditioning | $75,184 | $3,302 | - | - | $75,184 | - | |
TOTAL RECOMMENDED | $78,179 | $11,017 |
$2,296
38,993
kWh
|
$652
-
kW-mo/yr
|
$75,184 | $47 | ||
TOTAL IMPLEMENTED | $909 | $4,165 |
$615
10,719
kWh
|
$247
-
kW-mo/yr
|
- | $47 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs