| Assessment Year | 2002 |
|---|---|
| Principal Product | Flexographic laser and letterpress printing, computer typesetting, color |
| NAICS |
n/a
|
| SIC | 2759: Commercial Printing, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 135 |
| Plant Area |
150,000
ft2
|
| Annual Production | 250,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $199,678 | 3,357,233 |
kWh
|
$0.059 |
| Electricity Demand | $7,992 | 667 |
kW-mo/yr
|
$11.98 |
| Electricity Fees | $40,518 | - |
|
- |
| Natural Gas | $40,595 | 5,377 |
MMBtu
|
$7.55 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $174,998 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,479 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $6,071 | $1,750 | - | - |
$6,071
-
MMBtu
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,718 | $4,200 |
$11,735
149,489
kWh
|
$983
-
kW-mo/yr
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,806 | $9,004 |
$5,056
65,078
kWh
|
$750
-
kW-mo/yr
|
- | - | |
| 04 | 2.7135: Install occupancy sensors | $444 | $1,400 |
$322
4,364
kWh
|
$122
-
kW-mo/yr
|
- | - | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $8,673 | - |
$8,673
109,982
kWh
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,714 | $120 |
$3,392
39,116
kWh
|
$322
-
kW-mo/yr
|
- | - | |
| 07 | 2.7145: Install skylights | $5,831 | $6,702 |
$5,831
74,280
kWh
|
- | - | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $464 | $230 |
$420
5,352
kWh
|
$44
-
kW-mo/yr
|
- | - | |
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $77,357 | $15,800 |
$71,378
909,269
kWh
|
$5,979
-
kW-mo/yr
|
- | - | |
| 10 | 4.521: Clear and rent existing space | $53,920 | $5,308 | - | - | - | $53,920 | |
| TOTAL RECOMMENDED | $174,998 | $44,514 |
$106,807
1,356,930
kWh
|
$8,200
-
kW-mo/yr
|
$6,071
-
MMBtu
|
$53,920 | ||
| TOTAL IMPLEMENTED | $14,479 | $9,004 |
$13,729
175,060
kWh
|
$750
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs