Assessment Year | 2002 |
---|---|
Principal Product | Plastic storage containers |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
763,000
ft2
|
Annual Production | 100,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $823,575 | 26,013,680 |
kWh
|
$0.032 |
Electricity Demand | $463,946 | 43,170 |
kW-mo/yr
|
$10.75 |
Electricity Fees | $114,834 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $194,280 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,576 | $4,955 | n/a |
$1,264
31,772
kWh
|
$1,312
-
kW-mo/yr
|
- | - |
02 | 2.7135: Install occupancy sensors | $784 | $975 | n/a |
$402
10,104
kWh
|
$382
-
kW-mo/yr
|
- | - |
03 | 2.6218: Turn off equipment when not in use | $346 | $1,200 | n/a |
$148
3,722
kWh
|
$198
-
kW-mo/yr
|
- | - |
04 | 2.4133: Use most efficient type of electric motors | $5,056 | $3,042 | n/a |
$3,786
571,176
kWh
|
$1,270
-
kW-mo/yr
|
- | - |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $48,861 | $260 | n/a |
$35,593
894,969
kWh
|
$13,268
-
kW-mo/yr
|
- | - |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $36,742 | $16,800 | n/a |
$27,508
691,690
kWh
|
$9,234
-
kW-mo/yr
|
- | - |
07 | 3.4151: Minimize water usage | $775 | $60 | n/a | - | - |
$775
-
Tgal
|
- |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $77,282 | $10,792 | n/a | - | - | - | $77,282 |
09 | 4.454: Modify startup/shutdown times | $21,858 | $486 | n/a | - | - | - | $21,858 |
TOTAL RECOMMENDED | $194,280 | $38,570 |
$68,701
2,203,433
kWh
|
$25,664
-
kW-mo/yr
|
$775
-
Tgal
|
$99,140 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs