Assessment Year | 2001 |
---|---|
Principal Product | Custom wood and aluminum exterior and interior |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
75,000
ft2
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 4,662
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $99,078 | 1,643,320 |
kWh
|
$0.060 |
Electricity Demand | $13,132 | 5,266 |
kW-mo/yr
|
$2.49 |
Electricity Fees | $9,876 | - |
|
- |
Natural Gas | $10,466 | 1,357 |
MMBtu
|
$7.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,869 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $702 | $1,200 |
$352
8,784
kWh
|
$350
-
kW-mo/yr
|
- | |
02 | 2.7124: Make a practice of turning off lights when not needed | $225 | $225 |
$225
5,616
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,216 | $6,238 |
$1,096
27,335
kWh
|
$1,120
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,534 | $15 |
$894
22,300
kWh
|
$640
-
kW-mo/yr
|
- | |
05 | 3.6192: Use a less expensive method of waste removal | $3,192 | $60 | - | - | $3,192 | |
TOTAL RECOMMENDED | $7,869 | $7,738 |
$2,567
64,035
kWh
|
$2,110
-
kW-mo/yr
|
$3,192 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs