| Assessment Year | 2001 |
|---|---|
| Principal Product | Custom wood and aluminum exterior and interior |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
75,000
ft2
|
| Annual Production | 10,000
pieces
|
| Production Hrs. Annual | 4,662
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $99,078 | 1,643,320 |
kWh
|
$0.060 |
| Electricity Demand | $13,132 | 5,266 |
kW-mo/yr
|
$2.49 |
| Electricity Fees | $9,876 | - |
|
- |
| Natural Gas | $10,466 | 1,357 |
MMBtu
|
$7.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,869 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $702 | $1,200 |
$352
8,784
kWh
|
$350
-
kW-mo/yr
|
- | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $225 | $225 |
$225
5,616
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,216 | $6,238 |
$1,096
27,335
kWh
|
$1,120
-
kW-mo/yr
|
- | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,534 | $15 |
$894
22,300
kWh
|
$640
-
kW-mo/yr
|
- | |
| 05 | 3.6192: Use a less expensive method of waste removal | $3,192 | $60 | - | - | $3,192 | |
| TOTAL RECOMMENDED | $7,869 | $7,738 |
$2,567
64,035
kWh
|
$2,110
-
kW-mo/yr
|
$3,192 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs