| Assessment Year | 2001 |
|---|---|
| Principal Product | Corrugated Cardboard Boxes |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 92 |
| Plant Area |
260,000
ft2
|
| Annual Production | 600,000
thousand feet
|
| Production Hrs. Annual | 4,200
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $425,417 | 6,155,314 |
kWh
|
$0.069 |
| Electricity Demand | $49,837 | 17,208 |
kW-mo/yr
|
$2.90 |
| Electricity Fees | $36,647 | - |
|
- |
| Natural Gas | $23,654 | 22,425 |
MMBtu
|
$1.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $820,015 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $818,623 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $120 | $525 |
$120
2,359
kWh
|
- | |
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,174 | $300 |
$1,174
12,974
kWh
|
- | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,824 | $30 |
$1,824
37,332
kWh
|
- | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,272 | $60 |
$1,272
23,314
kWh
|
- | |
| 05 | 4.322: Eliminate old stock and modify inventory control | $815,625 | $640 | - | $815,625 | |
| TOTAL RECOMMENDED | $820,015 | $1,555 |
$4,390
75,979
kWh
|
$815,625 | ||
| TOTAL IMPLEMENTED | $818,623 | $970 |
$2,998
50,306
kWh
|
$815,625 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs