| Assessment Year | 1999 |
|---|---|
| Principal Product | Concrete |
| NAICS |
n/a
|
| SIC | 3272: Concrete Products, Except Block and Brick |
| Sales Range | $1 M to 5M |
| # of Employees | 55 |
| Plant Area |
110,000
ft2
|
| Annual Production | 450,000
ton
|
| Production Hrs. Annual | 5,450
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $55,329 | 819,461 |
kWh
|
$0.068 |
| Electricity Demand | $12,924 | 4,929 |
kW-mo/yr
|
$2.62 |
| Electricity Fees | $4,916 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $207,672 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $206,647 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $405 | $70 |
$405
5,569
kWh
|
- | - | - | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $461 | $60 |
$399
5,569
kWh
|
$62
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $1,802 | $2,140 |
$1,657
22,860
kWh
|
$145
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.4314: Use synthetic lubricant | $148 | $360 |
$34
586
kWh
|
$3
-
kW-mo/yr
|
$12
-
gal
|
- | - | $99 | |
| 05 | 4.821: Pay bills on time to avoid late fees | $728 | $60 | - | - | - | - | $728 | - | |
| 06 | 4.445: Install equipment to move product | $203,979 | $64,000 |
$(-12,893.0)
(-177,315)
kWh
|
$(-1,128.0)
-
kW-mo/yr
|
- | $218,000 | - | - | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $149 | $15 | - | - | - | - | $149 | - | |
| TOTAL RECOMMENDED | $207,672 | $66,705 |
$(-10,398.0)
(-142,731)
kWh
|
$(-918.0)
-
kW-mo/yr
|
$12
-
gal
|
$218,000 | $877 | $99 | ||
| TOTAL IMPLEMENTED | $206,647 | $66,270 |
$(-10,432.0)
(-143,317)
kWh
|
$(-921.0)
-
kW-mo/yr
|
- | $218,000 | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs