Assessment Year | 1999 |
---|---|
Principal Product | Refuse collection vehicles |
NAICS |
n/a
|
SIC | 3713: Truck and Bus Bodies |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
125,000
ft2
|
Annual Production | 450
pieces
|
Production Hrs. Annual | 2,295
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,877 | 1,457,210 |
kWh
|
$0.076 |
Electricity Demand | $7,778 | 4,548 |
kW-mo/yr
|
$1.71 |
Electricity Fees | $8,053 | - |
|
- |
Natural Gas | $884 | 56 |
MMBtu
|
$15.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $495,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $89,667 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,716 | $1,300 |
$1,716
35,756
kWh
|
- | - | - | - | - | - | - | |
02 | 2.7135: Install occupancy sensors | $393 | $825 |
$198
4,103
kWh
|
$195
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $711 | $3,018 |
$374
7,913
kWh
|
$337
-
kW-mo/yr
|
- | - | - | - | - | - | |
04 | 3.5111: Filter and reuse hydraulic oil | $3,052 | $1,600 |
$(-2.0)
(-293)
kWh
|
- |
$3,384
-
gal
|
- | $(-106.0) | $(-224.0) | - | - | |
05 | 3.6192: Use a less expensive method of waste removal | $6,862 | $30 | - | - | - |
$6,862
-
lb
|
- | - | - | - | |
06 | 3.6192: Use a less expensive method of waste removal | $87,240 | $10,375 | - | - |
$87,240
-
gal
|
- | - | - | - | - | |
07 | 4.111: Add equipment/ operators to reduce production bottleneck | $270,903 | $520,000 |
$(-1,471.0)
(-30,481)
kWh
|
$(-1,646.0)
-
kW-mo/yr
|
- | - | $(-100,980.0) | - | $375,000 | - | |
08 | 4.311: Schedule deliveries according to demand | $124,999 | $146,360 | - | - | - | - | - | - | - | $124,999 | |
TOTAL RECOMMENDED | $495,876 | $683,508 |
$815
16,998
kWh
|
$(-1,114.0)
-
kW-mo/yr
|
$90,624
-
gal
|
$6,862
-
lb
|
$(-101,086.0) | $(-224.0) | $375,000 | $124,999 | ||
TOTAL IMPLEMENTED | $89,667 | $14,693 |
$2,090
43,669
kWh
|
$337
-
kW-mo/yr
|
$87,240
-
gal
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs