Assessment Year | 1999 |
---|---|
Principal Product | High purity glass precision assemblies and fiberoptics |
NAICS |
n/a
|
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
100,000
ft2
|
Annual Production | 32,152
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $195,508 | 2,775,498 |
kWh
|
$0.070 |
Electricity Demand | $11,750 | 6,756 |
kW-mo/yr
|
$1.74 |
Electricity Fees | $221,202 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $72,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $60,670 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $297 | $398 |
$221
4,689
kWh
|
$76
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $526 | $551 |
$288
5,862
kWh
|
$52
-
kW-mo/yr
|
- | $90 | - | $96 | - | |
03 | 2.7135: Install occupancy sensors | $1,628 | $2,550 |
$1,219
25,205
kWh
|
$409
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,416 | $15,077 |
$6,238
128,664
kWh
|
$2,178
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.2515: Use optimum thickness insulation | $3,847 | $383 |
$3,847
79,426
kWh
|
- | - | - | - | - | - | |
06 | 2.6218: Turn off equipment when not in use | $76 | $45 |
$76
1,465
kWh
|
- | - | - | - | - | - | |
07 | 3.1293: Separate treatments for each type of solution and recycle | $890 | $120 | - | - |
$890
-
gal
|
- | - | - | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $300 | $120 | - | - | - | - | $144 | - | $156 | |
09 | 3.6192: Use a less expensive method of waste removal | $480 | $60 | - | - | - | - | $480 | - | - | |
10 | 4.112: Replace old machine with new automatic multi-station tool | $56,000 | $36,200 | - | - | - | $56,000 | - | - | - | |
TOTAL RECOMMENDED | $72,460 | $55,504 |
$11,889
245,311
kWh
|
$2,715
-
kW-mo/yr
|
$890
-
gal
|
$56,090 | $624 | $96 | $156 | ||
TOTAL IMPLEMENTED | $60,670 | $37,532 |
$4,356
89,977
kWh
|
$128
-
kW-mo/yr
|
- | $56,090 | - | $96 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs