Assessment Year | 1998 |
---|---|
Principal Product | Capital Equipment for Semiconductor Industry |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 325 |
Plant Area |
152,000
ft2
|
Annual Production | 23,000
pieces
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $473,716 | 8,729,191 |
kWh
|
$0.054 |
Electricity Demand | $46,981 | 16,911 |
kW-mo/yr
|
$2.78 |
Electricity Fees | $47,151 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,384 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $791 | $2,613 |
$480
12,016
kWh
|
$311
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,106 | $60 |
$603
38,687
kWh
|
$1,503
-
kW-mo/yr
|
- | - | - | |
03 | 3.6192: Use a less expensive method of waste removal | $6,136 | $60 | - | - |
$6,136
-
lb
|
- | - | |
04 | 3.4115: Recover and reuse cooling water | $1,500 | $3,000 |
$(-890.0)
(-22,860)
kWh
|
- | - |
$2,390
-
Tgal
|
- | |
05 | 4.812: Apply for investment incentives | $2,851 | $60 | - | - | - | - | $2,851 | |
TOTAL RECOMMENDED | $13,384 | $5,793 |
$193
27,843
kWh
|
$1,814
-
kW-mo/yr
|
$6,136
-
lb
|
$2,390
-
Tgal
|
$2,851 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs