Assessment Year | 1998 |
---|---|
Principal Product | Commercial Printing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
30,000
ft2
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 5,730
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,051 | 1,276,964 |
kWh
|
$0.064 |
Electricity Demand | $36,340 | 4,717 |
kW-mo/yr
|
$7.70 |
Electricity Fees | $10,968 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $221,665 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,243 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $1,882 | $1,100 |
$1,882
26,964
kWh
|
- | - | - | - | - | - | |
02 | 2.7135: Install occupancy sensors | $465 | $1,200 |
$350
4,982
kWh
|
$115
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,438 | $10,732 |
$5,366
76,495
kWh
|
$1,072
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $6,108 | $4,800 |
$5,341
76,202
kWh
|
$767
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $916 | $1,089 |
$751
10,844
kWh
|
$165
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.7122: Disconnect ballasts | $354 | $15 |
$321
4,689
kWh
|
$33
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.7313: Recycle air for heating, ventilation and air conditioning | $358 | $15 |
$358
4,982
kWh
|
- | - | - | - | - | - | |
08 | 2.7224: Reduce space conditioning during non-working hours | $469 | $225 |
$469
6,741
kWh
|
- | - | - | - | - | - | |
09 | 2.4314: Use synthetic lubricant | $255 | $292 |
$141
2,052
kWh
|
$31
-
kW-mo/yr
|
$11
-
gal
|
- | - | - | $72 | |
10 | 3.6192: Use a less expensive method of waste removal | $15,720 | $60 | - | - | - | - | $3,220 | - | $12,500 | |
11 | 3.6192: Use a less expensive method of waste removal | $700 | $60 | - | - | - | - | $700 | - | - | |
12 | 4.113: Install refrigeration system to cool product | $188,000 | $450,000 | - | - | - | $108,000 | - | $80,000 | - | |
TOTAL RECOMMENDED | $221,665 | $469,588 |
$14,979
213,951
kWh
|
$2,183
-
kW-mo/yr
|
$11
-
gal
|
$108,000 | $3,920 | $80,000 | $12,572 | ||
TOTAL IMPLEMENTED | $17,243 | $360 |
$790
11,430
kWh
|
$33
-
kW-mo/yr
|
- | - | $3,920 | - | $12,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs