| Assessment Year | 1997 |
|---|---|
| Principal Product | Golf Accessories |
| NAICS |
n/a
|
| SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 283 |
| Plant Area |
80,000
ft2
|
| Annual Production | 515,000
pieces
|
| Production Hrs. Annual | 3,332
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $185,892 | 2,281,653 |
kWh
|
$0.081 |
| Electricity Demand | $12,803 | 7,558 |
kW-mo/yr
|
$1.69 |
| Electricity Fees | $14,428 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $241,062 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,454 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $410 | - |
$373
7,620
kWh
|
$37
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,976 | $140 |
$2,609
53,048
kWh
|
$367
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.4314: Use synthetic lubricant | $570 | $300 |
$471
9,672
kWh
|
$40
-
kW-mo/yr
|
$7
-
gal
|
- | - | - | $52 | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $8,593 | $12,000 |
$7,855
159,437
kWh
|
$738
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 2.2622: Replace existing chiller with high efficiency model | $10,117 | $7,000 |
$9,146
185,522
kWh
|
$971
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,411 | $3,015 |
$1,339
27,257
kWh
|
$72
-
kW-mo/yr
|
- | - | - | - | - | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,995 | $13,000 |
$4,379
88,804
kWh
|
$616
-
kW-mo/yr
|
- | - | - | - | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,635 | $3,183 |
$1,400
28,429
kWh
|
$235
-
kW-mo/yr
|
- | - | - | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $396 | $570 |
$376
7,620
kWh
|
$20
-
kW-mo/yr
|
- | - | - | - | - | |
| 10 | 2.7145: Install skylights | $1,207 | $1,200 |
$1,023
20,809
kWh
|
$184
-
kW-mo/yr
|
- | - | - | - | - | |
| 11 | 2.7111: Reduce illumination to minimum necessary levels | $2,037 | - |
$1,835
37,222
kWh
|
$202
-
kW-mo/yr
|
- | - | - | - | - | |
| 12 | 2.7135: Install occupancy sensors | $1,492 | $2,250 |
$1,384
28,136
kWh
|
$108
-
kW-mo/yr
|
- | - | - | - | - | |
| 13 | 3.5216: Recycle nonferrous dust | $176 | - | - | - | - |
$176
-
lb
|
- | - | - | |
| 14 | 4.512: Condense operation into one building | $205,047 | $15,000 |
$60,100
1,219,226
kWh
|
$8,489
-
kW-mo/yr
|
- | - | $6,494 | $129,964 | - | |
| TOTAL RECOMMENDED | $241,062 | $57,658 |
$92,290
1,872,802
kWh
|
$12,079
-
kW-mo/yr
|
$7
-
gal
|
$176
-
lb
|
$6,494 | $129,964 | $52 | ||
| TOTAL IMPLEMENTED | $7,454 | $3,893 |
$6,593
133,939
kWh
|
$861
-
kW-mo/yr
|
- | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs