Assessment Year | 1995 |
---|---|
Principal Product | Felt for Tennis Balls |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
60,000
ft2
|
Annual Production | 2,400
thousand feet
|
Production Hrs. Annual | 8,112
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $196,605 | 2,800,703 |
kWh
|
$0.070 |
Natural Gas | $123,825 | 25,988 |
MMBtu
|
$4.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,693 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,203 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,110 | $9,153 |
$11,110
178,488
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $1,499 | $1,135 |
$1,499
29,894
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $16,808 | $14,235 |
$16,808
251,465
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,608 | - |
$6,608
97,597
kWh
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $595 | $500 | - |
$595
-
MMBtu
|
|
06 | 2.2414: Use waste heat from hot flue gases to preheat | $3,952 | $7,500 | - |
$3,952
-
MMBtu
|
|
07 | 2.2511: Insulate bare equipment | $3,121 | $3,655 |
$505
8,206
kWh
|
$2,616
-
MMBtu
|
|
TOTAL RECOMMENDED | $43,693 | $36,178 |
$36,530
565,650
kWh
|
$7,163
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,203 | $500 |
$6,608
97,597
kWh
|
$595
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs