Assessment Year | 1995 |
---|---|
Principal Product | Polyvinyl Chloride Pipe |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 53 |
Plant Area |
65,000
ft2
|
Annual Production | 55,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $459,773 | 7,448,711 |
kWh
|
$0.062 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,213 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $43,929 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $14,313 | $11,527 |
$14,313
260,258
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,148 | - |
$5,148
92,907
kWh
|
|
03 | 2.3137: Use power during off-peak periods | $7,700 | $50 |
$7,700
-
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,333 | $650 |
$13,333
247,948
kWh
|
|
05 | 2.4314: Use synthetic lubricant | $5,086 | $5,202 |
$5,086
38,980
kWh
|
|
06 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $4,366 | $20,000 |
$4,366
93,200
kWh
|
|
07 | 2.2622: Replace existing chiller with high efficiency model | $11,926 | $31,350 |
$11,926
212,485
kWh
|
|
08 | 2.2511: Insulate bare equipment | $8,844 | $6,860 |
$8,844
163,247
kWh
|
|
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,497 | $12,300 |
$3,497
65,064
kWh
|
|
TOTAL RECOMMENDED | $74,213 | $87,939 |
$74,213
1,174,089
kWh
|
||
TOTAL IMPLEMENTED | $43,929 | $29,729 |
$43,929
612,250
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs