Assessment Year 1995
Principal Product Commercial and Military/Aircraft and Rocketry Parts
NAICS
n/a
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 80,000
ft2
Annual Production 12,000,000
pieces
Production Hrs. Annual 6,344
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $195,131 2,543,669
kWh
Natural Gas $2,300 351
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $40,764 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4133: Use most efficient type of electric motors $5,172 $6,162 n/a $5,172
62,720
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,785 - n/a $1,785
19,637
kWh
-
03 2.4314: Use synthetic lubricant $2,539 $300 n/a $2,539
20,223
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $187 $100 n/a $187
2,638
kWh
-
05 2.2437: Recover waste heat from equipment $460 $850 n/a - $460
-
MMBtu
06 2.7231: Use radiant heater for spot heating $1,638 $8,104 n/a - $1,638
-
MMBtu
07 2.7241: Install outside air damper / economizer on hvac unit $4,656 $7,000 n/a $4,656
86,166
kWh
-
08 2.7232: Replace existing hvac unit with high efficiency model $13,386 $47,025 n/a $13,386
173,212
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $4,847 $20,429 n/a $4,847
73,271
kWh
-
10 2.7142: Utilize higher efficiency lamps and/or ballasts $597 $1,649 n/a $597
9,086
kWh
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $4,937 $16,594 n/a $4,937
70,926
kWh
-
12 2.7135: Install occupancy sensors $560 $750 n/a $560
10,258
kWh
-
TOTAL RECOMMENDED $40,764 $108,963 $38,666
528,137
kWh
$2,098
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs