Assessment Year | 1995 |
---|---|
Principal Product | Phone Booths & Generator Enclosures |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 77 |
Plant Area |
46,715
ft2
|
Annual Production | 3,680
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,326 | 362,544 |
kWh
|
$0.12 |
LPG | $12,507 | 906 |
MMBtu
|
$13.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,890 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,535 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $4,355 | $8,475 | - |
$4,355
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $317 | $150 | - |
$317
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,444 | $2,213 |
$1,444
12,896
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $320 | - |
$320
2,931
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $454 | $150 |
$454
4,689
kWh
|
- | |
TOTAL RECOMMENDED | $6,890 | $10,988 |
$2,218
20,516
kWh
|
$4,672
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,535 | $2,513 |
$2,218
20,516
kWh
|
$317
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs