Assessment Year | 1995 |
---|---|
Principal Product | Plastic Injection Molding |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 180 |
Plant Area |
75,000
ft2
|
Annual Production | 4,500,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $343,767 | 4,204,279 |
kWh
|
$0.082 |
Natural Gas | $757 | 99 |
MMBtu
|
$7.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,431 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $213 | $660 |
$213
2,638
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $14,635 | $9,240 |
$14,635
179,074
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,314 | - |
$1,314
16,120
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,337 | $150 |
$1,337
16,413
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,720 | $7,298 |
$4,720
57,737
kWh
|
|
06 | 2.7135: Install occupancy sensors | $212 | $201 |
$212
2,638
kWh
|
|
TOTAL RECOMMENDED | $22,431 | $17,549 |
$22,431
274,620
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs