| Assessment Year | 1994 |
|---|---|
| Principal Product | steel doors |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $5 M to 10M |
| # of Employees | 135 |
| Plant Area |
102,500
ft2
|
| Annual Production | 72,000
pieces
|
| Production Hrs. Annual | 5,434
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,955 | 998,828 |
kWh
|
$0.078 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,390 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,337 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,486 | $11,750 |
$7,486
95,838
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,926 | $9,358 |
$2,926
37,515
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $162 | $307 |
$162
2,052
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $2,407 | $3,205 |
$2,407
30,774
kWh
|
|
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $160 | $100 |
$160
2,052
kWh
|
|
| 06 | 2.4314: Use synthetic lubricant | $1,210 | $1,410 |
$1,210
6,741
kWh
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,039 | $350 |
$1,039
13,189
kWh
|
|
| TOTAL RECOMMENDED | $15,390 | $26,480 |
$15,390
188,161
kWh
|
||
| TOTAL IMPLEMENTED | $5,337 | $11,425 |
$5,337
59,497
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs