Assessment Year | 1994 |
---|---|
Principal Product | Sheet Metal Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $5 M to 10M |
# of Employees | 125 |
Plant Area |
55,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 8,112
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $252,022 | 3,398,886 |
kWh
|
$0.074 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,576 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,419 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,756 | $825 |
$1,756
26,084
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,292 | $1,342 |
$14,292
192,849
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $546 | $500 |
$546
8,206
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,997 | $585 |
$2,997
44,549
kWh
|
|
05 | 2.7135: Install occupancy sensors | $7,611 | $26,535 |
$7,611
112,837
kWh
|
|
06 | 2.4133: Use most efficient type of electric motors | $374 | $2,060 |
$374
5,569
kWh
|
|
TOTAL RECOMMENDED | $27,576 | $31,847 |
$27,576
390,094
kWh
|
||
TOTAL IMPLEMENTED | $19,419 | $4,812 |
$19,419
269,051
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs