Assessment Year | 1993 |
---|---|
Principal Product | AEROSPACE COMPONENTS |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 34 |
Plant Area |
n/a
|
Annual Production | 3,000
pieces
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $76,724 | 744,138 |
kWh
|
$0.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,289 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,400 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $52 | - |
$67
586
kWh
|
$(-15.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $82 | $240 |
$82
879
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,427 | $2,720 |
$1,493
14,361
kWh
|
$(-66.0) | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,236 | $300 |
$1,236
12,016
kWh
|
- | |
05 | 2.4312: Improve lubrication practices | $604 | $880 |
$133
1,172
kWh
|
$471 | |
06 | 2.4133: Use most efficient type of electric motors | $317 | $587 |
$317
2,931
kWh
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $571 | - |
$571
5,569
kWh
|
- | |
TOTAL RECOMMENDED | $4,289 | $4,727 |
$3,899
37,514
kWh
|
$390 | ||
TOTAL IMPLEMENTED | $2,400 | $4,187 |
$2,010
19,050
kWh
|
$390 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs