Assessment Year 1993
Principal Product CABLE CONNECTORS (TV)
NAICS
n/a
SIC 3451: Screw Machine Products
Sales Range $5
M
to 10
M
# of Employees 85
Plant Area
n/a
Annual Production 14,000,000
pieces
Production Hrs. Annual 5,303
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $61,806 863,130
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,984 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,998

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $775 $1,485 $897
12,603
kWh
$(-122.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $243 $420 $268
3,810
kWh
$(-25.0)
03 2.7142: Utilize higher efficiency lamps and/or ballasts $900 $1,166 $900
12,603
kWh
-
04 2.7135: Install occupancy sensors $191 $375 $191
2,638
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $160 $136 $195
2,638
kWh
$(-35.0)
06 2.7142: Utilize higher efficiency lamps and/or ballasts $191 $260 $191
2,638
kWh
-
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,290 $650 $3,290
46,014
kWh
-
08 2.4314: Use synthetic lubricant $2,626 $4,776 $848
11,723
kWh
$1,778
09 2.4133: Use most efficient type of electric motors $628 $1,380 $628
8,792
kWh
-
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,254 - $1,254
17,585
kWh
-
11 2.2614: Use cooling tower or economizer to replace chiller cooling $704 $2,450 $704
9,965
kWh
-
12 2.7261: Install timers and/or thermostats $1,022 $1,120 $1,022
14,361
kWh
-
TOTAL RECOMMENDED $11,984 $14,218 $10,388
145,370
kWh
$1,596
TOTAL IMPLEMENTED $9,998 $9,967 $8,402
117,526
kWh
$1,596
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs