| Assessment Year | 1993 |
|---|---|
| Principal Product | SHEET METAL PRODUCTS |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $500 k to 1M |
| # of Employees | 15 |
| Plant Area |
n/a
|
| Annual Production | 200,000
pieces
|
| Production Hrs. Annual | 2,211
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $12,294 | 97,890 |
kWh
|
$0.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,222 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $629 | $1,000 |
$629
4,982
kWh
|
|
| 02 | 2.4314: Use synthetic lubricant | $228 | - |
$228
1,758
kWh
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $926 | $400 |
$926
7,327
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $157 | $208 |
$157
1,172
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $359 | - |
$359
2,931
kWh
|
|
| 06 | 2.7234: Use heat pump for space conditioning | $357 | $1,420 |
$357
2,931
kWh
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,526 | $5,661 |
$1,526
12,309
kWh
|
|
| 08 | 2.8114: Change rate schedules or other changes in utility service | $1,040 | $3,550 |
$1,040
-
kWh
|
|
| TOTAL RECOMMENDED | $5,222 | $12,239 |
$5,222
33,410
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs