Assessment Year 1992
Principal Product ALUMINUM TUBING
NAICS
n/a
SIC 3354: Aluminum Extruded Products
Sales Range $10
M
to 50
M
# of Employees 350
Plant Area
n/a
Annual Production 24,000,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $819,641 11,536,929
kWh
Natural Gas $1,134,665 254,015
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $57,228 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $2,838 $28,119 $2,838
39,859
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $762 - $762
10,844
kWh
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,183 $4,100 $1,183
16,706
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $3,487 $1,000 $3,487
49,238
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,744 $2,500 $12,744
179,367
kWh
-
06 2.2511: Insulate bare equipment $15,532 $1,099 $15,532
218,640
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,761 $5,217 $1,916
26,964
kWh
$(-155.0)
08 2.7142: Utilize higher efficiency lamps and/or ballasts $18,921 $21,494 $18,921
266,413
kWh
-
TOTAL RECOMMENDED $57,228 $63,529 $57,383
808,031
kWh
$(-155.0)
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs