| Assessment Year | 1992 |
|---|---|
| Principal Product | HIGH DENSITY ELECTRONIC CIRCUITS |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $10 M to 50M |
| # of Employees | 124 |
| Plant Area |
n/a
|
| Annual Production | 66,000
pieces
|
| Production Hrs. Annual | 6,320
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $186,642 | 2,762,016 |
kWh
|
$0.068 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $53,052 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7226: Use computer programs to optimize hvac performance | $15,953 | $17,550 |
$15,953
235,932
kWh
|
- | - | |
| 02 | 2.7234: Use heat pump for space conditioning | $25,121 | $152,160 |
$25,121
371,630
kWh
|
- | - | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $4,000 | - |
$4,000
59,203
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,555 | $14,446 |
$2,795
41,325
kWh
|
- | $(-240.0) | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $598 | $1,215 |
$598
8,792
kWh
|
- | - | |
| 06 | 2.2511: Insulate bare equipment | $128 | $80 | - |
$128
-
MMBtu
|
- | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,790 | $1,000 |
$3,790
55,979
kWh
|
- | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $364 | $100 |
$364
5,275
kWh
|
- | - | |
| 09 | 2.4133: Use most efficient type of electric motors | $543 | $2,649 |
$543
7,913
kWh
|
- | - | |
| TOTAL RECOMMENDED | $53,052 | $189,200 |
$53,164
786,049
kWh
|
$128
-
MMBtu
|
$(-240.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs