ITAC Assessment: AS0062
ITAC logo
ITAC Assessment: AS0062
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product POTATO CHIPS
NAICS
n/a
SIC 2096: Potato Chips, Corn Chips, and Similar Snacks
Sales Range $5
M
to 10
M
# of Employees 36
Plant Area
n/a
Annual Production 210,000
pieces
Production Hrs. Annual 5,616
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $19,402 197,538
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,371 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,371

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7226: Use computer programs to optimize hvac performance $2,190 $800 $2,190
22,274
kWh
- -
02 2.7233: Use properly designed and sized hvac equipment $1,689 $8,870 $1,689
17,292
kWh
- -
03 2.7422: Plant trees or shrubs near windows to shield from sunlight $222 $320 $222
2,345
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $469 $1,293 $495
4,982
kWh
- $(-26.0)
05 2.4133: Use most efficient type of electric motors $100 $606 $100
1,172
kWh
- -
06 2.2425: Use flue gases to heat process or service water $4,458 $25,000 - $4,458
-
MMBtu
-
07 2.2511: Insulate bare equipment $607 $183 $593
6,155
kWh
$14
-
MMBtu
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $636 $100 $636
6,448
kWh
- -
TOTAL RECOMMENDED $10,371 $37,172 $5,925
60,668
kWh
$4,472
-
MMBtu
$(-26.0)
TOTAL IMPLEMENTED $10,371 $37,172 $5,925
60,668
kWh
$4,472
-
MMBtu
$(-26.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs