| Assessment Year | 1992 |
|---|---|
| Principal Product | PLASTIC MOLDED ENCLOSURE |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 840,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $451,995 | 7,323,271 |
kWh
|
$0.062 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $68,545 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3111: Heat water during off-peak periods and store for later use | $16,293 | $64,125 |
$16,293
-
kWh
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $15,736 | $68,000 |
$15,736
254,982
kWh
|
- | |
| 03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $6,959 | $10,500 |
$6,959
112,837
kWh
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $961 | $2,033 |
$961
15,533
kWh
|
- | |
| 05 | 2.2515: Use optimum thickness insulation | $727 | $3,700 |
$727
11,723
kWh
|
- | |
| 06 | 2.7234: Use heat pump for space conditioning | $15,185 | $26,340 |
$15,185
245,897
kWh
|
- | |
| 07 | 2.7226: Use computer programs to optimize hvac performance | $6,710 | $2,400 |
$6,710
108,734
kWh
|
- | |
| 08 | 2.7422: Plant trees or shrubs near windows to shield from sunlight | $441 | $1,200 |
$441
7,034
kWh
|
- | |
| 09 | 2.4133: Use most efficient type of electric motors | $1,731 | $6,791 |
$1,731
28,136
kWh
|
- | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $537 | $236 |
$607
9,965
kWh
|
$(-70.0) | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,265 | $3,424 |
$3,265
53,048
kWh
|
- | |
| TOTAL RECOMMENDED | $68,545 | $188,749 |
$68,615
847,889
kWh
|
$(-70.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs