Assessment Year | 1992 |
---|---|
Principal Product | STRUCTURAL FIBERGLASS |
NAICS |
n/a
|
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 108 |
Plant Area |
n/a
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $633,149 | 10,043,376 |
kWh
|
$0.063 |
Natural Gas | $265,444 | 115,853 |
MMBtu
|
$2.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $150,704 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,812 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $125,830 | $500,000 |
$229,328
3,779,895
kWh
|
$(-65,698.0)
-
MMBtu
|
$(-37,800.0) | |
02 | 2.8122: Use utility controlled power management | $12,703 | $25,000 |
$12,703
-
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $3,278 | $18,136 |
$3,278
52,169
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,936 | $1,803 |
$3,856
61,254
kWh
|
- | $80 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15 | $147 |
$47
1,172
kWh
|
- | $(-32.0) | |
06 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $3,062 | $2,400 |
$3,062
48,652
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,880 | $100 |
$1,880
29,894
kWh
|
- | - | |
TOTAL RECOMMENDED | $150,704 | $547,586 |
$254,154
3,973,036
kWh
|
$(-65,698.0)
-
MMBtu
|
$(-37,752.0) | ||
TOTAL IMPLEMENTED | $21,812 | $45,186 |
$21,764
144,489
kWh
|
- | $48 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs