| Assessment Year | 1990 |
|---|---|
| Principal Product | KITCHEN CABINETS |
| NAICS |
n/a
|
| SIC | 2434: Wood Kitchen Cabinets |
| Sales Range | $1 M to 5M |
| # of Employees | 45 |
| Plant Area |
n/a
|
| Annual Production | 47,000
pieces
|
| Production Hrs. Annual | 2,167
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $55,142 | 538,394 |
kWh
|
$0.10 |
| Natural Gas | $1,437 | 226 |
MMBtu
|
$6.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,188 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,438 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $414 | $863 |
$414
4,103
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $915 | - |
$915
8,792
kWh
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,109 | $1,000 |
$5,109
49,824
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $327 | $107 |
$327
3,224
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $423 | $706 |
$423
4,103
kWh
|
|
| TOTAL RECOMMENDED | $7,188 | $2,676 |
$7,188
70,046
kWh
|
||
| TOTAL IMPLEMENTED | $6,438 | $1,863 |
$6,438
62,719
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs