Assessment Year 1990
Principal Product TURBINE BLADES & DISKS
NAICS
n/a
SIC 3724: Aircraft Engines and Engine Parts
Sales Range $10
M
to 50
M
# of Employees 170
Plant Area
n/a
Annual Production 378,000
pieces
Production Hrs. Annual 8,520
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $306,408 4,932,005
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $67,746 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,030

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $2,166 $3,217 $2,166
34,877
kWh
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $11,178 - $11,178
179,953
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,719 $1,000 $9,719
156,506
kWh
04 2.4239: Eliminate or reduce compressed air usage $5,450 $1,200 $5,450
87,632
kWh
05 2.4231: Reduce the pressure of compressed air to the minimum required $1,966 $100 $1,966
31,653
kWh
06 2.7142: Utilize higher efficiency lamps and/or ballasts $4,623 $1,058 $4,623
74,443
kWh
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,544 $2,708 $2,544
41,032
kWh
08 2.7422: Plant trees or shrubs near windows to shield from sunlight $7,935 $5,300 $7,935
127,784
kWh
09 2.8114: Change rate schedules or other changes in utility service $22,165 $30,000 $22,165
-
kWh
TOTAL RECOMMENDED $67,746 $44,583 $67,746
733,880
kWh
TOTAL IMPLEMENTED $30,030 $4,866 $30,030
483,587
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs