Assessment Year | 2000 |
---|---|
Principal Product | Sawmill Equipment |
NAICS |
n/a
|
SIC | 3553: Woodworking Machinery |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
150,000
ft2
|
Annual Production | 350
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,436 | 1,401,524 |
kWh
|
$0.032 |
Electricity Demand | $42,446 | 2,822 |
kW-mo/yr
|
$15.04 |
Natural Gas | $19,658 | 3,235 |
MMBtu
|
$6.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,118 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,457 | $2,178 |
$809
25,205
kWh
|
$648
-
kW-mo/yr
|
- | - | - | |
02 | 2.7122: Disconnect ballasts | $6,341 | $2,605 |
$3,568
108,441
kWh
|
$2,773
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $26 | - |
$14
586
kWh
|
$12
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $101 | $1,780 |
$56
1,758
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,334 | $6,713 |
$981
30,774
kWh
|
$1,353
-
kW-mo/yr
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,153 | $120 |
$779
24,326
kWh
|
$374
-
kW-mo/yr
|
- | - | - | |
07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $7,335 | $500 | - | - |
$827
-
Tgal
|
$6,508 | - | |
08 | 4.653: Maintain/enlarge a stock of spare parts | $80,371 | $16,150 | - | - | - | - | $80,371 | |
TOTAL RECOMMENDED | $99,118 | $30,046 |
$6,207
191,090
kWh
|
$5,205
-
kW-mo/yr
|
$827
-
Tgal
|
$6,508 | $80,371 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs