Assessment Year | 2000 |
---|---|
Principal Product | Industrial Machinery |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
130,000
ft2
|
Annual Production | 16,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,427 | 1,361,079 |
kWh
|
$0.032 |
Electricity Demand | $50,113 | 4,332 |
kW-mo/yr
|
$11.57 |
Natural Gas | $17,633 | 3,237 |
MMBtu
|
$5.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $76,159 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $217 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,606 | $4,020 |
$7,188
117,819
kWh
|
$3,418
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $672 | $828 |
$448
586
kWh
|
$224
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $217 | - |
$144
2,345
kWh
|
$73
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,146 | $4,224 |
$2,049
29,894
kWh
|
$1,097
-
kW-mo/yr
|
- | - | - | |
05 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $20,376 | $1,300 | - | - |
$15,647
-
Tgal
|
$4,729 | - | |
06 | 4.452: Eliminate shift | $41,142 | - | - | - | - | - | $41,142 | |
TOTAL RECOMMENDED | $76,159 | $10,372 |
$9,829
150,644
kWh
|
$4,812
-
kW-mo/yr
|
$15,647
-
Tgal
|
$4,729 | $41,142 | ||
TOTAL IMPLEMENTED | $217 | - |
$144
2,345
kWh
|
$73
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs