Assessment Year | 1997 |
---|---|
Principal Product | Breading Batter |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 60 |
Plant Area |
125,000
ft2
|
Annual Production | 120,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $137,120 | 4,306,858 |
kWh
|
$0.032 |
Electricity Demand | $52,625 | 9,435 |
kW-mo/yr
|
$5.58 |
Natural Gas | $156,980 | 50,250 |
MMBtu
|
$3.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,953 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,373 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,449 | $575 |
$1,100
34,291
kWh
|
$349
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $1,541 | $2,100 |
$1,207
37,808
kWh
|
$334
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,366 | $45 |
$1,987
62,134
kWh
|
$379
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $427 | $80 |
$345
10,844
kWh
|
$82
-
kW-mo/yr
|
- | - | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $4,571 | $14,000 | - | - |
$4,571
-
MMBtu
|
- | - | |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $5,922 | - | - | - | - |
$5,922
-
lb
|
- | |
07 | 3.5217: Reuse / recycle/ sell paper products | $544 | - | - | - | - |
$544
-
lb
|
- | |
08 | 4.423: Move product using mechanical means | $30,133 | $37,400 | - | - | - | - | $30,133 | |
TOTAL RECOMMENDED | $46,953 | $54,200 |
$4,639
145,077
kWh
|
$1,144
-
kW-mo/yr
|
$4,571
-
MMBtu
|
$6,466
-
lb
|
$30,133 | ||
TOTAL IMPLEMENTED | $10,373 | $2,145 |
$3,194
99,942
kWh
|
$713
-
kW-mo/yr
|
- |
$6,466
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs