Assessment Year | 1995 |
---|---|
Principal Product | Truck Transmissions |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 325 |
Plant Area |
220,000
ft2
|
Annual Production | 47,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $671,834 | 20,245,897 |
kWh
|
$0.033 |
Natural Gas | $49,600 | 14,043 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $191,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $47,150 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $800 | $584 |
$800
20,516
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $10,013 | $14,650 |
$10,013
325,029
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,864 | $350 |
$9,864
320,340
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,547 | $25 |
$1,547
50,410
kWh
|
- | - | |
05 | 2.3212: Optimize plant power factor | $5,669 | $13,220 |
$5,669
-
kWh
|
- | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $139,091 | $55,000 |
$188,617
2,878,371
kWh
|
$(-49,526.0)
-
MMBtu
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $408 | - |
$408
13,189
kWh
|
- | - | |
08 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $18,582 | $500 |
$18,582
743,552
kWh
|
- | - | |
09 | 2.6218: Turn off equipment when not in use | $2,696 | $200 |
$2,696
107,855
kWh
|
- | - | |
10 | 3.7311: Maintain machines to reduce leaks | $3,240 | $1,000 | - | - |
$3,240
-
Tgal
|
|
TOTAL RECOMMENDED | $191,910 | $85,529 |
$238,196
4,459,262
kWh
|
$(-49,526.0)
-
MMBtu
|
$3,240
-
Tgal
|
||
TOTAL IMPLEMENTED | $47,150 | $17,309 |
$43,910
1,580,891
kWh
|
- |
$3,240
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs