| Assessment Year | 1994 |
|---|---|
| Principal Product | Commercial Lumber |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $5 M to 10M |
| # of Employees | 18 |
| Plant Area |
10,000
ft2
|
| Annual Production | 15,000,000
thousand feet
|
| Production Hrs. Annual | 2,086
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $95,563 | 1,074,443 |
kWh
|
$0.089 |
| Natural Gas | $6,700 | 1,356 |
MMBtu
|
$4.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,084 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,637 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,414 | $445 |
$1,414
15,826
kWh
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $7,832 | $6,280 |
$7,832
87,925
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $391 | $106 |
$391
4,396
kWh
|
- | - | |
| 04 | 2.4134: Replace electric motor with fossil fuel engine | $21,447 | $19,000 |
$32,976
370,750
kWh
|
$(-9,529.0)
-
MMBtu
|
$(-2,000.0) | |
| TOTAL RECOMMENDED | $31,084 | $25,831 |
$42,613
478,897
kWh
|
$(-9,529.0)
-
MMBtu
|
$(-2,000.0) | ||
| TOTAL IMPLEMENTED | $9,637 | $6,831 |
$9,637
108,147
kWh
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs