| Assessment Year | 1994 |
|---|---|
| Principal Product | Preserved Railroad Crossties |
| NAICS |
n/a
|
| SIC | 2491: Wood Preserving |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
100,000
ft2
|
| Annual Production | 2,500,000
pieces
|
| Production Hrs. Annual | 8,134
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $275,850 | 3,334,701 |
kWh
|
$0.083 |
| Natural Gas | $272,440 | 99,934 |
MMBtu
|
$2.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $148,055 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $148,055 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2135: Repair and eliminate steam leaks | $56,354 | $5,100 | - |
$56,354
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,424 | $756 |
$2,424
29,308
kWh
|
- | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $2,396 | $180 |
$2,396
29,015
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,362 | $699 |
$1,362
16,413
kWh
|
- | |
| 05 | 2.3212: Optimize plant power factor | $52,744 | $41,355 |
$52,744
-
kWh
|
- | |
| 06 | 2.2136: Install / repair insulation on steam lines | $10,636 | $2,021 | - |
$10,636
-
MMBtu
|
|
| 07 | 2.4133: Use most efficient type of electric motors | $3,289 | $2,750 |
$3,289
39,859
kWh
|
- | |
| 08 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,724 | - |
$7,724
-
kWh
|
- | |
| 09 | 2.2153: Close off unneeded steam lines | $4,040 | $100 | - |
$4,040
-
MMBtu
|
|
| 10 | 2.2511: Insulate bare equipment | $7,086 | $11,543 | - |
$7,086
-
MMBtu
|
|
| TOTAL RECOMMENDED | $148,055 | $64,504 |
$69,939
114,595
kWh
|
$78,116
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $148,055 | $64,504 |
$69,939
114,595
kWh
|
$78,116
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs