Assessment Year | 1994 |
---|---|
Principal Product | Wire Cloth |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
130,000
ft2
|
Annual Production | 12,000,000
thousand feet
|
Production Hrs. Annual | 6,257
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,240 | 1,196,952 |
kWh
|
$0.074 |
Natural Gas | $12,502 | 2,237 |
MMBtu
|
$5.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,275 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,275 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $9,495 | $210 |
$9,495
128,664
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $798 | $974 |
$798
10,844
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,118 | $1,349 |
$4,118
55,979
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $154 | $50 |
$154
2,052
kWh
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $9,986 | - |
$9,986
-
kWh
|
|
06 | 2.8114: Change rate schedules or other changes in utility service | $724 | - |
$724
-
kWh
|
|
TOTAL RECOMMENDED | $25,275 | $2,583 |
$25,275
197,539
kWh
|
||
TOTAL IMPLEMENTED | $25,275 | $2,583 |
$25,275
197,539
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs