| Assessment Year | 1994 |
|---|---|
| Principal Product | Automotive Service Equip. |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
215,636
ft2
|
| Annual Production | 12,204
pieces
|
| Production Hrs. Annual | 2,086
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $262,474 | 5,092,028 |
kWh
|
$0.052 |
| Natural Gas | $80,350 | 22,614 |
MMBtu
|
$3.55 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,632 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,305 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $5,096 | $1,300 |
$5,096
98,769
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,200 | $1,860 |
$2,200
42,790
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $585 | $200 |
$585
11,430
kWh
|
- | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,424 | $3,240 |
$776
14,947
kWh
|
$1,648
-
MMBtu
|
|
| 05 | 2.7245: Use direct air supply to exhaust hoods | $7,327 | $300 |
$7,327
142,145
kWh
|
- | |
| TOTAL RECOMMENDED | $17,632 | $6,900 |
$15,984
310,081
kWh
|
$1,648
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,305 | $6,600 |
$8,657
167,936
kWh
|
$1,648
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs