| Assessment Year | 1993 |
|---|---|
| Principal Product | Hydraulic Valves |
| NAICS |
n/a
|
| SIC | 3491: Industrial Valves |
| Sales Range | $50 M to 100M |
| # of Employees | 470 |
| Plant Area |
232,000
ft2
|
| Annual Production | 90,000
pieces
|
| Production Hrs. Annual | 6,633
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $895,310 | 14,826,202 |
kWh
|
$0.060 |
| Natural Gas | $23,977 | 5,747 |
MMBtu
|
$4.17 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $81,123 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,562 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,666 | $740 |
$12,666
112,544
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $14,046 | $6,750 |
$14,046
70,633
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,562 | $1,000 |
$5,562
54,220
kWh
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $5,187 | $14,712 |
$5,187
385,111
kWh
|
- | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $18,409 | $5,000 |
$19,487
53,048
kWh
|
$(-1,078.0)
-
MMBtu
|
|
| 06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $25,253 | $12,000 |
$29,096
216,002
kWh
|
$(-3,843.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $81,123 | $40,202 |
$86,044
891,558
kWh
|
$(-4,921.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,562 | $1,000 |
$5,562
54,220
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs