| Assessment Year | 1993 |
|---|---|
| Principal Product | Hardwood Cabinet Components |
| NAICS |
n/a
|
| SIC | 2434: Wood Kitchen Cabinets |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
86,250
ft2
|
| Annual Production | 10,000,000
thousand feet
|
| Production Hrs. Annual | 2,086
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $226,998 | 2,965,416 |
kWh
|
$0.077 |
| Wood | $47,704 | 110,940 |
MMBtu
|
$0.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $51,091 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,054 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $6,253 | $990 |
$6,253
81,770
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,429 | $2,535 |
$4,429
57,737
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $3,398 | $4,030 |
$3,398
44,549
kWh
|
- | |
| 04 | 2.2136: Install / repair insulation on steam lines | $3,974 | $2,000 | - |
$3,974
-
MMBtu
|
|
| 05 | 2.3137: Use power during off-peak periods | $33,037 | $330 |
$33,037
-
kWh
|
- | |
| TOTAL RECOMMENDED | $51,091 | $9,885 |
$47,117
184,056
kWh
|
$3,974
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $18,054 | $9,555 |
$14,080
184,056
kWh
|
$3,974
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs