Assessment Year | 1993 |
---|---|
Principal Product | Electric Motors |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
150,000
ft2
|
Annual Production | 7,800,000
pieces
|
Production Hrs. Annual | 6,257
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,462 | 3,347,597 |
kWh
|
$0.074 |
Natural Gas | $37,892 | 9,716 |
MMBtu
|
$3.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,761 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,113 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,309 | $1,740 |
$1,309
17,585
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,655 | $648 |
$4,655
63,013
kWh
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $8,684 | $890 |
$8,684
117,526
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,113 | $100 |
$1,113
14,947
kWh
|
|
TOTAL RECOMMENDED | $15,761 | $3,378 |
$15,761
213,071
kWh
|
||
TOTAL IMPLEMENTED | $1,113 | $100 |
$1,113
14,947
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs